Home >

Applications

Industry Applications

 

 

Dianbida Power Equipment (Jiangsu) Co., Ltd. is a professional manufacturer of domestic and imported generator sets, fully automatic generator sets, silent generator sets, and mobile generator sets. 

page-1-1

Hospital

page-1-1

School sector

page-1-1

Real estate

page-1-1

Livestock farming

page-1-1

Public facilities

page-1-1

Outdoor use

page-1-1

Telecom industry

page-1-1

Rail & road

page-1-1

Petrochemical industry

page-1-1

Mining & metallurgy

page-1-1

Financial industry

page-1-1

Backup power for factories

 Hospital Dedicated Generator Sets

page-1-1

Hospital dedicated generator sets are high-performance diesel generator units developed by the engineering team of Dianbida Power Equipment based on in-depth market research conducted by the marketing department. These units are designed to provide stable and reliable power supply for hospitals under any emergency conditions.

Currently, hundreds of hospitals both domestically and internationally are using Dianbida's complete power solutions, earning widespread recognition within the healthcare industry.

 

Product Requirements & Challenges

1. Operating Conditions
The generator set is capable of reliable operation under the following conditions:

  • Continuous operation at rated power for 24 hours (including 1 hour of 10% overload every 12 hours)
  • Altitude: ≤ 1000 meters
  • Ambient temperature: -15°C to 40°C (customized solutions available for extreme environments)

2. Low Noise Operation
Ultra-low noise design ensures a quiet environment for medical staff and patients. This is especially critical for operating rooms, allowing surgical procedures to be carried out without disturbance while also ensuring a restful recovery environment for patients.

3. Essential Protection Systems
The generator set is equipped with automatic shutdown and alarm functions under the following fault conditions:

  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Failed start

The unit adopts an automatic start mode and is equipped with an AMF (Automatic Mains Failure) system and ATS (Automatic Transfer Switch):

  • Automatic start within <5 seconds after power failure (adjustable)
  • Three consecutive automatic start attempts
  • Load transfer time between mains and generator: <10 seconds
  • Total power restoration time: <12 seconds
  • After mains power recovery, the generator continues running for 0–300 seconds (adjustable) before automatic shutdown

4. Stable Performance & High Reliability

  • Mean Time Between Failures (MTBF): ≥ 2000 hours
  • No-load voltage adjustment range: 95%–105% of rated voltage

Solution

Dianbida provides high-performance, stable, and low-noise generator sets equipped with the PLC-5220 control system featuring AMF functionality. When integrated with ATS, the system ensures immediate power supply once the main power source fails.

The generator sets are powered by low-emission engines compliant with European and American standards, ensuring environmental friendliness alongside performance.

With RS232 or RS485/422 communication interfaces, the system can be connected to a computer for remote monitoring, enabling remote control, signaling, and measurement. This allows for fully automatic and unattended operation.

 

Advantages

Complete turnkey solutions reduce technical requirements for users, making operation and maintenance simple and efficient

Advanced control system with AMF function enables automatic start, shutdown, and alarm under multiple monitoring conditions

Optional ATS (built-in ATS available for small generator sets)

Ultra-low noise: units below 30KVA achieve ≤60 dB(A) at 7 meters

Stable performance with MTBF ≥ 2000 hours

Compact structure with optional configurations for extreme cold or high-temperature environments

Custom design and development available to meet specific customer requirements

 

School Dedicated Generator Sets

page-1-1

School dedicated generator sets are high-performance diesel generator systems developed by Dianbida Power Equipment's engineering team based on comprehensive market research. They are designed to provide stable and reliable backup power for schools during emergencies, ensuring uninterrupted teaching activities and campus operations.

Dianbida has delivered power solutions to numerous educational institutions worldwide, gaining strong recognition in the education sector.

 

Product Requirements & Challenges

1. Operating Conditions

  • The generator set operates reliably under the following conditions:
  • Continuous operation at rated power for 24 hours (including 1 hour of 10% overload every 12 hours)
  • Altitude: ≤ 1000 meters
  • Ambient temperature: -15°C to 40°C (custom configurations available for extreme environments)

2. Low Noise Operation
Ultra-low noise design is essential for maintaining a quiet campus environment. It ensures that teaching activities, examinations, and student rest are not disturbed by generator operation.

3. Essential Protection Systems
The generator set automatically shuts down and provides alarm signals under the following fault conditions:

  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Failed start

The unit features automatic start mode with AMF (Automatic Mains Failure) and ATS (Automatic Transfer Switch):

  • Automatic start within <5 seconds after power failure (adjustable)
  • Three consecutive automatic start attempts
  • Load transfer time between mains and generator: <10 seconds
  • Total restoration time: <12 seconds
  • After mains recovery, the generator continues running for 0–300 seconds (adjustable) before automatic shutdown

4. Stable Performance & High Reliability

  • Mean Time Between Failures (MTBF): ≥ 2000 hours
  • No-load voltage adjustment range: 95%–105% of rated voltage

Solution

Dianbida provides efficient and stable generator solutions tailored for educational environments. The units adopt a low-noise design and are equipped with a PLC-5220 control system with AMF functionality. When integrated with ATS, the system ensures immediate power supply in case of grid failure, preventing disruptions to teaching, campus safety systems, and essential facilities.

Powered by low-emission engines compliant with European and American standards, the generator sets offer both environmental performance and operational reliability.

With RS232 or RS485/422 communication interfaces, the system supports remote monitoring, including remote control, signaling, and data measurement, enabling fully automatic and unattended operation across campus facilities.

Advantages

Complete turnkey solutions simplify installation, operation, and maintenance for school management

Intelligent control system with AMF function enables automatic start, shutdown, and alarm under multiple monitoring conditions

Optional ATS (built-in ATS available for small generator sets)

Ultra-low noise: units below 30KVA achieve ≤60 dB(A) at 7 meters

Stable performance with MTBF ≥ 2000 hours

Compact structure with optional configurations for cold or high-temperature regions

Custom design and development available for specific campus requirements

 

Diesel Generator Sets for Real Estate & Building Projects

page-1-1

Diesel generator sets for real estate applications typically include open-type generators, canopy (silent) generators, and containerized power stations. They are widely used as backup and emergency power solutions for residential and commercial buildings.

By function, these generator sets can be categorized into:

  • Standard generator sets
  • Automatic generator sets
  • Monitoring-enabled generator sets
  • Automatic transfer generator sets (ATS integrated)
  • Automatic paralleling generator systems

Canopy-type generators can be further divided into:

  • Weatherproof canopy generator sets
  • Low-noise generator sets
  • Super silent generator sets
  • Containerized power stations

 

Key Requirements & Challenges

1. Operating Conditions

  • Generator sets must operate reliably under the following conditions:
  • Continuous operation at rated power for up to 24 hours, including 10% overload for 1 hour every 12 hours
  • Altitude ≤ 1000 meters
  • Ambient temperature range from -15°C to 40°C (customized solutions available for extreme environments)

2. Low Noise Operation
Low noise levels are essential to ensure normal operation of buildings and facilities in urban environments worldwide.

3. Essential Protection & Control Systems

  • Automatic start system required
  • Equipped with AMF (Auto Mains Failure) function and ATS (Automatic Transfer Switch)
  • Generator starts automatically within <20 seconds after power failure (adjustable delay, with up to 3 start attempts)
  • Full load transfer between mains and generator within <20 seconds, ensuring total power restoration within 30 seconds
  • After mains recovery, the generator continues running for 0–300 seconds (adjustable) before automatic shutdown for cooling

4. Stability & Reliability

  • Mean Time Between Failures (MTBF) ≥ 1000 hours
  • No-load voltage adjustment range: 95%–105% of rated voltage

Solution

Our diesel generator sets deliver high performance and stable operation, featuring low-noise design and equipped with the PLC-5220 control system with AMF function. When integrated with ATS, the system ensures that backup power is supplied immediately once the main power fails.

This combination of stability, low noise, and intelligent automatic control fully meets the strict requirements of modern buildings, supporting reliable operation across residential, commercial, and mixed-use developments worldwide.

Advantages

  • Complete product and solution offering, reducing technical complexity for users
  • AMF-enabled control system with automatic start, shutdown, monitoring, and alarm functions
  • ATS optional or built-in for small generator sets
  • Ultra-low noise operation (≤60 dB(A) at 7 meters for units below 30kVA)
  • High reliability with MTBF ≥ 1000 hours
  • Compact design, adaptable to both cold and high-temperature environments
  • Custom engineering solutions available to meet specific project requirements

 

Diesel Generator Sets for Livestock Farming

page-1-1

Diesel generator sets for livestock farming applications typically include open-type generators, canopy (silent) generators, and containerized power stations. They are widely used as emergency and backup power solutions for farms, ranches, and agricultural facilities.

By function, these generator sets can be categorized into:

  • Standard generator sets
  • Automatic generator sets
  • Monitoring-enabled generator sets
  • Automatic transfer generator sets (ATS integrated)
  • Automatic paralleling generator systems

Canopy-type generators can be further divided into:

  • Weatherproof canopy generator sets
  • Low-noise generator sets
  • Super silent generator sets
  • Containerized power stations

Key Requirements & Challenges

1. Operating Conditions

  • Reliable operation at altitudes up to 3000 meters
  • Ambient temperature range from -15°C to 40°C (custom configurations available for extreme environments)

2. High Stability & Reliability

  • Mean Time Between Failures (MTBF) ≥ 2000 hours, ensuring continuous and dependable operation for critical farm systems

3. Convenient Refueling & Water Supply with Safety Protection

  • Equipped with external fuel filling system with locking function
  • Typically designed with large-capacity fuel tanks to support 12–24 hours continuous operation

4. Compact Design & Customization Capability

  • Suitable for outdoor use with compact structure and easy mobility
  • Custom design available, including special colors, specifications, and standards to meet specific project or industry requirements

Solution

Our diesel generator sets provide stable performance, easy operation, and low maintenance, combined with low-noise design and convenient external fuel and water systems. These features ensure reliable power supply for livestock farms, even in remote or harsh environments.

Advantages

  • Complete product and solution offering, simplifying installation, operation, and maintenance
  • AMF-enabled control system for automatic start, shutdown, monitoring, and alarm functions
  • ATS optional or built-in for smaller generator sets
  • Ultra-low noise operation (≤60 dB(A) at 7 meters for units below 30kVA)
  • High reliability with MTBF ≥ 2000 hours
  • Compact and adaptable design for both cold and high-temperature environments
  • Flexible customization to meet specific farm or project requirements

This solution is ideal for livestock farms, poultry houses, dairy operations, and agricultural facilities that require reliable, automatic, and low-noise backup power to ensure uninterrupted feeding, ventilation, and environmental control systems.